Browsing by Author "Anjrini, Mustafa"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item Comparative performance analysis of a combined cooling system with mechanical and adsorption cycles(Pergamon-Elsevier Science, 2020-10-01) Kılıç, Muhsin; Anjrini, Mustafa; Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği.; 0000-0003-2113-4510; 0000-0003-1153-7631; O-2253-2015; DSX-5806-2022; 57202677637; 57218171703This article aims to analyze comparatively the performance of a combined refrigeration system consists of an upper section (adsorption chiller) and a lower section (vapor compression chiller (VCC)). The arrangement of the adsorption cooling chiller (ACC) depends on two adsorption beds that use silica gel/water as a working pair. The beds are driven by heat comes from outside heat sources with low-grade temperatures <= 100 degrees C. Whereas in the bottom section, different types of refrigerants (R410A, R152A, R1234yf, R1270, and R32) have been utilized to be driven by the mechanical compressor. This paper focuses on the evaluation of the refrigerants in VCC and the working pair in ACC by means of coefficient of performance (COP) and energy-saving ratio (ES) in this refrigeration system. The computed results reveal that the refrigerants show the same behavior while calculating the COP of the combined system and the VCC in the combined system, with the high values reached up to 0.5 and 8.8 for R152A, respectively. Meanwhile, the energy-saving reached up to 65.3%. The increase ratio (IR) of the COP of the VCC is also calculated with the highest value reached up to 188%. The effects of the ambient air temperature, the heat source temperature, the cycle time and the evaporation temperature on the system performance and the required mass of adsorbent in the adsorption beds are investigated for the design of ACC-VCC combined system.Publication Comparative performance evaluation of the mechanical and adsorption hybrid cooling systems for the cascaded and the serial connected evaporators configurations(Elsevier, 2021-09-22) Kılıç, Muhsin; Anjrini, Mustafa; KILIÇ, MUHSİN; Anjrini, Mustafa; Bursa Uludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü.; 0000-0003-2113-4510; 0000-0003-1153-7631; O-2253-2015; DSX-5806-2022The goal of this study is to investigate comparatively the performance of an integrated cooling system comprised of an adsorption cooling cycle (ADC) and a vapor cooling cycle (VCC) with two different configurations, namely (cascaded and serial connected evaporators). The ADC chiller relies on the thermal compressor with two adsorption beds, which use three different adsorbents (RD silica gel, RD silica gel 2060, and silica gel- LiCl) and water (adsorbate) as a working pair separately. The thermal compressor operates by outside waste or solar-based thermal sources that have low-level temperatures below 100 degrees C. R152A was selected for the VCC chiller. This article pays particular attention to evaluating the ADC adsorbents and (ADC-VCC) connection configurations based on the first and second law of thermodynamics. The investigations have been implemented at different ADC evaporator temperatures. The effect of adsorption cycle time and ambient temperature on the overall coefficient of performance were also investigated and discussed for both configurations. Furthermore, the ADC and VCC coefficient of performances and the performance ratio (PR) were investigated at different ADC evaporator temperatures. The relation between the adsorbent mass and the cooling load was also discussed in this paper.Item A novel parametric performance analysis of hybrid refrigeration cycles with mechanical and adsorption compression(Bursa Uludağ Üniversitesi, 2021-06-28) Anjrini, Mustafa; Kılıç, Muhsin; Bursa Uludağ Üniversitesi/Fen Bilimleri Enstitüsü/Makine Mühendisliği Anabilim Dalı.; 0000-0003-1153-7631Çevre sorunları ve büyük enerji tüketimine yol açan önemli teknolojilerden biri, buhar sıkıştırmalı soğutma döngüsünü (VCC) kullanmaktır. Bu nedenle soğutma endüstrilerinde yeni enerji kaynaklarını kullanan yeni teknolojiler düşünülmelidir. Bu yeni teknolojilerden biri adsorpsiyon soğutma çevrimidir (ACC). ACC sisteminin düşük performans değerleri gibi dezavantajlarının üstesinden gelmek için kullanılabilecek en umut verici yöntemlerden birisinin VCC sistemleri olduğu kabul edilmektedir. Adsorpsiyonlu soğutma sisteminin etkenliğini artırmak için son zamanlarda birçok iyileştirme ve ilerlemeler yapılmıştır. Bu araştırmada, buhar sıkıştırmalı soğutma sistemi (VCC) ile adsorpsiyonlu soğutma sistemi (ACC) hibrit bir soğutma sistemi oluşturmak amacıyla birleştirilmiştir. İki soğutma sistemi arasındaki fark sıkıştırma tipidir. ACC sistemi termal sıkıştırma tipini kullanırken, VCC sistemi mekanik sıkıştırma tipini kullanır. Bu çalışmanın ana hedefi olarak, kombine soğutma sisteminin farklı çalışma koşullarındaki performansını araştırmak için bir matematiksel kod yazılmış ve doğrulanmıştır. Bu çalışmanın ilk bölümünde, VCC ünitesinde farklı soğutucu akışkanlar ve ACC ünitesinde silika jel / su çifti kullanılarak önerilen kombine soğutma sisteminin enerji tasarrufu ve ekserji kavramı dikkate alınarak performansı araştırılmıştır. Ana hedefi, en yüksek performansı ve enerji tasarrufunu sağlayan en iyi soğutucu akışkanı ortaya çıkarmak ve farklı VCC evaporatör sıcaklıklarında adsorban kütlesi ile adsorpsiyon çevrimi süresi arasındaki ilişkiyi araştırmaktır. Bu çalışmanın ikinci kısmında, birkaç ACC evaporatöründe ve ısıtma sıcaklıklarında dört farklı adsorban kullanılarak ACC'nin performans katsayısı (COP) ve spesifik soğutma gücünü (SCP) araştırılmıştır. Üçüncü bölümde ise farklı ACC evaporatör sıcaklıklarında ACC ünitesinde üç farklı adsorban kullanılarak birkaç ortam sıcaklığı ve adsorpsiyon çevrimi süreleri için iki farklı (ACCVCC) kombine soğutma sistemi konfigürasyonu (seri ve paralel) performans açısından değerlendirilmiştir.