Person:
BAYKARA, MEHMET

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Organizational Unit

Job Title

Last Name

BAYKARA

First Name

MEHMET

Name

Search Results

Now showing 1 - 10 of 11
  • Publication
    Intraocular lens elongation technique with haptic modification for sulcus implantation
    (Galenos Publ House, 2022-08-01) Efe, Ayşe Çetin; BAYKARA, MEHMET; Gündüz, Gamze Uçan; UÇAN GÜNDÜZ, GAMZE; Yurttaş, Ceren; YURTTAŞ, CEREN; Bursa Uludağ Üniversitesi/Tıp Fakültesi/Oftalmoloji Anabilim Dalı.; Bursa Uludağ Üniversitesi/Tıp Fakültesi/Anestezi ve Reanimasyon Anabilim Dalı.; 0000-0002-5555-1649; 0000-0002-5458-1686; AAH-6661-2021
    Objectives: To define a haptic modification technique to increase the overall length of the intraocular lens (IOL) and evaluate the postoperative outcomes of patients in whom this technique was applied.Materials and Methods: The preoperative and postoperative characteristics of patients who underwent modified IOL implantation into the sulcus between May 2019 and December 2019 were evaluated. Modified Sensar AR40e lenses with hydrophobic acrylic optic and polymethylmethacrylate haptics were implanted to all eyes. Before implanting the IOL, the haptics were grasped with two toothless forceps and bent to elongate the total diameter of the IOL from 13.0 mm to 14.5 mm.Results: The study included 11 eyes of 11 patients who underwent modified three-piece IOL implantation into the sulcus due to insufficient capsular support. The mean age of the patients was 53.9 +/- 12.2 years. The mean axial length was 24.13 +/- 1.93 mm. Sulcus implantation was required due to aphakia in 9 eyes and IOL dislocation in 2 eyes. No haptic breakage occurred during the IOL modification technique or implantation. The mean preoperative best corrected visual acuity (BCVA) was 0.88 +/- 1.1 logMAR, while postoperative BCVA was 0.28 +/- 0.30 logMAR. No IOL dislocation or decentration was observed during 6-month postoperative follow-up.Conclusion: The larger diameter lenses obtained with this inexpensive and easily applicable technique may allow a more stable sulcus implantation in eyes with inadequate capsular support.
  • Publication
    A modified continuous suturing technique for amniotic membrane fixation after chemical corneal injury: An octagonal graft
    (Galenos Publ House, 2022-10-01) Baykara, Mehmet; BAYKARA, MEHMET; Sarı, Esin Söğütlü; SÖĞÜTLÜ SARI, ESİN; Yurttaş, Ceren; YURTTAŞ, CEREN; Kırıştıoğlu, Mehmet Ömer; KIRIŞTIOĞLU, MEHMET ÖMER; Bursa Uludağ Üniversitesi/Tıp Fakültesi/Oftalmoloji Anabilim Dalı.; Bursa Uludağ Üniversitesi/Tıp Fakültesi/Anestezi ve Reanimasyon Anabilim Dalı.; 0000-0002-5555-1649; JBU-3309-2023
    This case report aims to describe a modified continuous suturing technique for firm fixation of a human amniotic membrane graft in a patient with persistent epithelial defect (PED) after a chemical eye injury. As a result of this technique, the amniotic membrane (AM) was firmly fixed to the corneal surface with eight continuous and locked episcleral sutures that resembled an octagon graft. This technique was performed in a 14-year-old patient with PED after a chemical corneal burn. Three weeks after the surgery, the PED was completely healed. This simple continuous suturing technique can allow firm and stable fixation of AM grafts on the ocular surface in cases of PED after chemical burn. It may prevent early loss of the graft and facilitate corneal epithelial wound healing.
  • Publication
    Evaluation of occupational closed globe eye
    (Derman Medical Publ, 2015-06-01) Budak, Berna Akova; Kıvanç, Sertaç Argün; KIVANÇ, SERTAÇ ARGUN; Başkaya, Kevser; Baykara, Mehmet; BAYKARA, MEHMET; Yücel, Ahmet Ali; YÜCEL, AHMET ALİ; Bursa Uludağ Üniversitesi/Tıp Fakültesi/Göz Hastalıkları Anabilim Dalı.; 0000-0003-0995-5260; 0000-0002-5555-1649; ABE-3033-2020; AAH-6518-2021; ABI-7051-2020
    Aim: To evaluate closed glob injuries related to occupational accidents of patients who had official occupational accident records. Material and Method: The medical records of patients with ocular injuries who referred to Department of Ophthalmology or emergency of Uludag University, School of Medicine between January 2010 and December 2013 with official occupational accident report were retrospectively reviewed. The patients with closed globe injuries following trauma were included. Age, sex, the injured eye, the cause of the trauma, whether the precautions were taken or not by the patient, the damage due to trauma were recorded. Results: According to the official records, 108 patients referred to our clinic with closed globe injury related to occupational accident. One hundred twenty eyes of 108 patients (2 females, 106 males) were evaluated. The mean age of the patients was 33 +/- 8.6 years. The most frequent cause of injury was foreign bodies on the ocular surface followed by blunt trauma. The mean age of the patients injured with foreign bodies was found to be significantly lower than the patients injured with blunt objects (p=0.039). Thirteen patients reported that they had used preventive equipment. Discussion: It is of utmost importance that the awareness of the workers should be raised and they should be educated about the use of preventive equipment to prevent the occupational eye injuries. The education of particularly the younger patients about the occupational injuries when they begin to work may decrease the rate of occupational accident related eye injuries.
  • Publication
    Evaluation of intraocular pressure change and anterior segment parameters after intravitreal bevacizumab injection - cannula size matters
    (Wolters Kluwer Medknow Publications, 2020-10-01) Hamidi, Nagihan A.; Güneş, Irfan B.; Baykara, Mehmet; Baykara, Mehmet; BAYKARA, MEHMET; Bursa Uludağ Üniversitesi/Tıp Fakültesi/OftalmolojiAnabilim Dalı.; ABI-7051-2020
    PURPOSE: To determine the changes in intraocular pressure (IOP) and anterior chamber parameters following intravitreal bevacizumab injection with different sizes of cannulas. METHODS: This clinical trial was conducted with 70 eyes of 70 patients who received an intravitreal injection of bevacizumab with 26 G (Group 1) or 30 G (Group 2) needle. Preinjection and postinjection 30th-min IOP and pentacam measurements were obtained. Anterior chamber depth (ACD), anterior chamber volume (ACV), central corneal thickness (CCT), corneal volume (CV), and iridocorneal angle (ICA) measurements were evaluated in pentacam. RESULTS: Preinjection mean IOP values in Group 1 and 2 were 14.7 +/- 3.29 mm Hg and 15.1 +/- 2.87 mm Hg, respectively. Postinjection mean IOP in Group 1 was 16.8 +/- 6.24 mm Hg and in Group 2 was 20.3 +/- 3.66 mm Hg. Postinjection mean IOP values were significantly higher than preinjection values in both groups (Group 1 P < 0.005 and Group 2 P < 0.001). IOP change was significantly higher in Group 2 after injection (P < 0.05). In both groups, the change in IOP found to be more significant in phakic eyes than pseudophakic eyes (Group 1 P < 0.001, Group 2 P < 0.001). CCT and CV were significantly higher in both groups 30 min after the injection than preinjection (Group 1 and Group 2; P < 0.01). In Group 2 ACD, ACV and ICA values were significantly lower than preinjection values (P < 0.05). CONCLUSION: Needle bore size is an important parameter that influences anterior segment parameters and IOP change in the intravitreal injection. IOP rise and anterior segment changes are more prominent with a thinner cannula.
  • Publication
    Intracorneal ring implantation using Intralase® with partial coverage of the cone in a patient after an alkaline injury
    (Dove Medical Press Ltd, 2011-01-01) Çakır, Hanefi; Utine, Canan Aslı; Baykara, Mehmet; BAYKARA, MEHMET; Uludağ Üniversitesi/Tıp Fakültesi/Göz Hastalıkları Anabilim Dalı.; ABI-7051-2020
    Purpose: To report the use of intracorneal ring segment (ICRS) implantation in a case of severe corneal thinning and irregularity secondary to alkali burn.Case report: A 33-year-old man who had a history of ocular alkali burn in the right eye was admitted. His best corrected visual acuity was 0.16 with manifest refraction of +5.00 (-7.00 x 180 degrees). Orbscan II (R) revealed steepening of >53 D superiorly, excessive thinning inferiorly with thinnest pachymetric reading of 269 mu m. Two KeraRing (R) segments, 200 mu m thick and 90 degrees arced, were implanted. During intrastromal channel creation by Intralase (R), the inferior half of the applanating cone was covered by a gelatinous paper to prevent the penetration of the laser beam into the anterior chamber. In the first year postoperation, best corrected visual acuity was 0.7 with manifest refraction of +1.50 (-3.50 x 35 degrees). Visante (R) opticial coherence tomography displayed ICRS at a depth of similar to 370 similar to mu m.Conclusion: ICRS implantation with this novel approach may be an option in eyes with severe corneal irregularity and thinning.
  • Publication
    Evaluation of the cataract surgery 2018 survey in terms of achieving refractive cataract surgery targets
    (Turkish Ophthalmological, 2021-01-01) Can, Izzet; Takmaz, Tamer; Ozdamar, Akif; Kamis, Umit; Akova, Yonca Aydin; Arslan, Osman Sevki; Devranoglu, Kazim; Gunenc, Uzeyir; Mutlu, Fatih Mehmet; Ozcan, Altan Atakan; Tasindi, Emrullah; Baykara, Mehmet; BAYKARA, MEHMET; Bursa Uludağ Üniversitesi/Tıp Fakültesi/Oftalmoloji Anabilim Dalı.; 0000-0001-9494-8756; 0000-0001-6359-4799; 0000-0002-5555-1649; 0000-0003-0504-0370; 0000-0002-7796-6511; AAT-6236-2020; F-1103-2018; ABI-7051-2020
    Objectives: The aim of this study was to show at what rate the technological equipment used in cataract surgery by Turkish ophthalmologists and their knowledge are reflected in practice and how up to date they are.Materials and Methods: A questionnaire conducted using SurveyMonkey was used to evaluate the answers to 17 questions from 823 members of the Turkish Ophthalmological Association. Results were evaluated in subgroups according to the participants' age, occupational status, institutions, and whether they conducted relevant academic activities, and the data were compared as inadequate, standard, and contemporary approaches according to the determined criteria.Results: Optical biometry devices were used at rates of 77.7% and 67.3% for intraocular lens (IOL) power calculations and keratometric measurements in preparation for cataract surgery, respectively. For IOL power calculation, third-generation formulas, especially the SRK-T, were used most commonly (46.2%), followed by second-generation formulas (21.9%), and fourth/fifth-generation formulas and multiple evaluations for different axial lengths (31.9%). The most common incision size was 2.8 mm (51.6%), while the percentage of 2.2 mm and shorter incisions considered to be neutral in terms of surgically induced astigmatism was 18.8%. When selecting incision location, approaches to reduce corneal astigmatism were reported by 28.9%, neutral approaches by 26.2%, and insensitive approaches by 44.9%. Additionally, 55.6% of participants never implanted toric IOLs and 50.7% did not use presbyopia-correcting IOLs. The proportion of surgeons who have experience with femtosecond laser-assisted cataract surgery was 10.3% and the rate of intracameral antibiotic injection at the end of the operation was 89.4%.Conclusion: It was seen that Turkish cataract surgeons were able to use high technology for surgical preparation and surgery at high rates, but this was not reflected in practice at same rate in terms of achieving contemporary standards of refractive cataract surgery.
  • Publication
    Visual outcomes at 12 months in patients following implantation of a diffractive multifocal intraocular
    (Springer, 2015-06-01) Baykara, Mehmet; Akova, Yonca Aydın; Arslan, Osman Sevki; Cinhüseyinoğlu, Necdet; Takmaz, Tamer; Gücükoğlu, Ahmet; Usta, Yıldırım Beyazıt; BAYKARA, MEHMET; Uludağ Üniversitesi/Tıp Fakültesi/Göz Hastalıkları Anabilim Dalı; ABI-7051-2020
    Introduction: The aim of this study was to assess distance, intermediate, and near visual acuity, contrast sensitivity, and patient satisfaction outcomes of a multifocal intraocular lens (IOL).Methods: This multicenter, prospective clinical study was conducted at seven study sites in Turkey. Patients who underwent bilateral cataract removal and implantation of a diffractive, acrylic, hydrophobic, multifocal IOL (Acriva UD Reviol MFB 625; VSY Biotechnology, Istanbul, Turkey) were included. The uncorrected and best corrected distance visual acuities (UCDVA and BCDVA), uncorrected and best corrected intermediate visual acuities (UCIVA and BCIVA), and uncorrected and best corrected near visual acuities (UCNVA and BCNVA) were measured preoperatively and at postoperative 1, 6, and 12 months. Distance and near visual acuity scores (VAS) contrast sensitivities were measured at these time points. Quality of life was evaluated by visual function-14 (VF-14) questionnaire.Results: Two hundred eyes of 100 patients were included. Monocular and binocular visual acuities at all distances showed improvement at postoperative 12 months compared to preoperative measurements (P < 0.001). Monocular and binocular UCIVA and binocular BCIVA at postoperative 12 months were significantly improved compared to measurements at 1 month (P < 0.001). Binocular contrast sensitivity at distance showed significant improvement from postoperative 1 month to postoperative 12 months, except for 3 cycles per degree (cpd; without glare) and 18 cpd (with glare). VAS improved from 75.96 at postoperative 1 month to 76.85 at postoperative 12 months. VF-14 score was 98.2 +/- 4.6.Conclusion: The Acriva UD Reviol MFB 625 appears to provide a good level of distance and near visual acuity, quality of life, and patient satisfaction. Further studies with longer follow-up will provide valuable insight into the long-term stability of these visual outcomes.
  • Publication
    Lamina cribrosa curvature index: A reliable parameter to screen diabetic patients for glaucoma
    (Sage Publications Ltd, 2022-11-04) İlhan, Esin; Tiskaoğlu, Nesime S.; Baykara, Mehmet; BAYKARA, MEHMET; Bursa Uludağ Üniversitesi/Tıp Fakültesi/Göz Hastalıkları Anabilim Dalı.; ABI-7051-2020
    Purpose To compare the translaminar pressure difference (TLPD), anterior lamina cribrosa surface depth (ALCSD), lamina cribrosa thickness (LCT), lamina cribrosa curvature index (LCCI) and peripapillary vascular density (pVD) in diabetic and healthy subjects. Methods Two hundred and eighty eyes of 140 patients (79 patients with diabetes mellitus (DM) without diabetic retinopathy (DR) and 61 healthy subjects) were enrolled in this study. Full ophthalmological examination, as well as optical coherence tomography (OCT) and OCT angiography (OCT-A) images, were analyzed. The ALCSD, LCT, LCCI were measured by enhanced depth imaging (EDI) OCT and the pVD by OCT-A. The TLPD values and relationships between TLPD and lamina cribrosa features and pVD were investigated in all subjects. Results The ALCSD and LCT were significantly shallower and thinner in diabetic patients when compared to healthy subjects (p <0.001). There was no significant difference in the LCCI in diabetics 13.717 (5.74-33.91) vs healthy subjects 13.118 (5.53-27.05) (p = 0.181). OCT-A revealed that the pVD in the diabetic group was significantly lower than in the non-diabetic group (p <0.001). TLPD was significantly lower in diabetic patients compared to healthy controls. Conclusion There are early changes in pVD and peripapillary vessel morphology in patients with DM. ALCSD and LCT were shallower and thinner in diabetic patients whereas the LCCI did not differ significantly. LCCI may be more valuable in assessing the lamina cribrosa (LC) of diabetic patients. The TLPD was found to be lower in diabetic patients compared to normal controls.
  • Publication
    Acanthamoeba keratitis and acanthamoeba conjunctivitis: A case report
    (Iranian Scientific Society Medical Entomology, 2020-04-01) Alver, Oktay; Baykara, Mehmet; Yuruk, Merve; Ülkü Tüzemen, Nazmiye; ALVER, OKTAY; BAYKARA, MEHMET; TÜZEMEN, NAZMİYE ÜLKÜ; Bursa Uludağ Üniversitesi/Tıp Fakültesi/Tıbbi Mikrobiyoloji Anabilim Dalı; Bursa Uludağ Üniversitesi/Tıp Fakültesi/Göz Hastalıkları Anabilim Dalı; 0000-0002-5555-1649; AAA-5241-2021; ABI-7051-2020; CGE-2103-2022
    Acanthamoeba species are vision-threatening agents by causing cornea infections known as Acanthamoeba keratitis. A 5 year-old kid with the complaints of erythema, eyelid edema, inflammation, limitation of eye movements in the right eye, and having no history of wearing contact lenses or trauma, was diagnosed of Acanthamoeba conjunctivitis through laboratory examinations in the Ophthalmology clinic. The visual sharpness of the patient improved after the treatment. A 44 year-old female patient suffering from pain, stinging, irritation, and inability to see in the left eye with the history of wearing contact lenses or trauma was diagnosed of Acanthamoeba keratitis through laboratory examinations. The agent was isolated and identified as "A. castellam" in the Genotype "T2". Examination of the left eye on the 15th day of treatment indicated that all complaints disappeared except for the cataract originated visual loss. However, the first diagnosis of Acanthamoeba keratitis appeared in the literature on a case with no history of wearing contact lenses and trauma it is found to be attention grabbing. We think that Acanthamoeba should not be ignored among microbial agents that cause eye infection with or without trauma and contact lens usage history.