Altındağ ilçesindeki bir ilköğretim okulunun çevre sağlığı yönünden değerlendirilmesi

dc.contributor.authorTemel, Fehminaz
dc.contributor.authorAkın, Levent
dc.contributor.authorVaizoğlu, Songül Acar
dc.contributor.authorKara, Özgür
dc.contributor.authorKara, Asil
dc.contributor.authorHalas, Aasım Misbah
dc.contributor.authorGurunaidu, Samy Subramaniam
dc.date.accessioned2021-03-29T13:01:07Z
dc.date.available2021-03-29T13:01:07Z
dc.date.issued2006-05-30
dc.description.abstractAltındağ İlçesindeki bir ilköğretim okulunda, okul çevre sağlığı açısından mevcut durumun saptanması, okulun Türk Standartları Enstitü sü 12014 sayılı standardına uygunluk durumunun değerlendirilmesi ve okul sınırları içinde Elektromanyetik alan (EMA) düzeylerinin, sınıflarda aydınlanma düzeyinin ölçülmesi amaçlanmıştır. Durum saptaması olan bu araştırmanın verileri, Nisan 2005 tarihinde, 1996’da kabul edilen Türk Standardı 12014 Okul Çevre Sağlığı Standardı (TS 12014 OÇSS) ve Türk Standardı 9518 (TS 9518) dikkate alınarak hazırlanan bilgi formuyla toplanmıştır. Aydınlanma düzeyi ölçümleri TES 1332 digital Light-meter ile, EMA ölçümü ise Bileşke Manye tik Alan Ölçen Gaussmetre (Triaxial ELF Magnetic Field meter) ile yapılmıştır. Sınıflarda ortalama öğrenci sayısı 35,8’dir. Sınıfların öğrenci başına düşen ortalama alan 1,34 m²/kişi, ortalama sınıf hacmi 3,7 m³/kişi bulunmuştur. Pencerelerin zeminden yüksekliği tüm sınıflarda 1,2 metrenin altındadır. Kızlar tuvaletinde lavabo ve kabin başına düşen öğrenci sayısı 48’dir. Erkekler tuvaletinde ise lavabo ve kabin başına düşen öğrenci sayısı 32’dir. Erkek ve kız öğrenciler için tuvaletlerdeki kabin ve pisuar sayısı yetersizdir. Okulda revir, mut fak ve yemekhane bulunmamaktadır. 25 sınıfta yapılan ölçümlerde ortalama aydınlanma 810 + 618 lüks, kütüphanede yapılan ölçümler sonucu ortalama değer 399 lüks bulunmuştur. Kapıya en yakın sıra grubunun ilk sırasında ortalama aydınlanma değeri 195 ± 118 lüks bulunmuştur. Sınıflarda önerilen en düşük aydınlanma değeri 200 lüks ve üzeridir. Sınıflar, kütüphane, idari odalar, bahçe ve koridorların tamamında EMA ortalaması, önerilen standart değer olan 2 mG’un altındadır. Bu çalışma sonucunda okul çevre sağlığı açısından bazı çevre sağlığı standartlarına uyulmadığı saptanmıştır. Okuldaki bu eksikliklerin giderilmesi ve yeni yapılacak okullarda okul çevre sağlığı göz önünde bulundurularak uluslararası standartlara uyulması önerilmektedir.tr_TR
dc.description.abstractThe research was conducted to determine the existing situation of a primary school in Altındağ, whether it is appropriate for the standards defined by the Institute of Turkish Standards, and the electromagnetic field levels in the school area and to measure the lighting levels in the classrooms. This descriptive survey’s data was collected in April 2005, by an information form prepared, considering the School Environmental Health Standards 12014 and Turkish Standards 9518. The average number of students in the classrooms were 35,8. The average classroom area per student was 1,34 m² and the average classroom volume per student was 3,7 m³. The windows’ height from the floor was below 1,2m. in all of the classes. In the toilets, the number of cabins and lavatories per female student was 48, while it was 32 for males. For male and female students the number of the cabins and the urinals were inadequate. In school there were no sick bay, kitchen and dining hall. The average lighting level was 810 + 618 lux in 25 of the classrooms, and 399 lux in the library. The average lighting level for the desks nearest to the door was 195 ± 118 lux. The lighting level accepted for the classrooms is ≥ 200 lux. The average electromagnetic field level for the classrooms, library, garden, managerial rooms and corridors were below the standards (2 mG). It was determined that some of the standards in the school didn’t conform to the school environmental health standards. The deficiencies in the school should be eliminated and when building new schools the international standards have to be applied considering the school envi ronmental health standards.en_US
dc.identifier.citationTemel, F. vd. (2006). "Altındağ ilçesindeki bir ilköğretim okulunun çevre sağlığı yönünden değerlendirilmesi". Uludağ Üniversitesi Tıp Fakültesi Dergisi, 32(1), 1-8.tr_TR
dc.identifier.endpage8tr_TR
dc.identifier.issn1300-414X
dc.identifier.issue1tr_TR
dc.identifier.startpage1tr_TR
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/420577
dc.identifier.urihttp://hdl.handle.net/11452/18575
dc.identifier.volume32tr_TR
dc.language.isoenen_US
dc.publisherUludağ Üniversitesitr_TR
dc.relation.journalUludağ Üniversitesi Tıp Fakültesi Dergisi / Journal of Uludag University Medical Facultytr_TR
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.relation.tezDoktoratr_TR
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectOkul çevre sağlığıtr_TR
dc.subjectAydınlanmatr_TR
dc.subjectElektromanyetik alantr_TR
dc.subjectTS 9518tr_TR
dc.subjectOkul çevre sağlığı standardıtr_TR
dc.subjectSchool environmental healthen_US
dc.subjectSchool environmental health standardsen_US
dc.subjectLightingen_US
dc.subjectElectromagnetic fielden_US
dc.titleAltındağ ilçesindeki bir ilköğretim okulunun çevre sağlığı yönünden değerlendirilmesitr_TR
dc.title.alternativeEnvironmental health assessment of a primary school in Altındağ districten_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
32_1_1.pdf
Size:
235.83 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: