Complications of primary placement of motility post in porous polyethylene implants during enucleation

dc.contributor.buuauthorYazıcı, Bülent
dc.contributor.buuauthorAkova, Berna
dc.contributor.buuauthorŞanlı, Özgür
dc.contributor.departmentUludağ Üniversitesi/Tıp Fakültesi/Oftalmoloji Bölümü.tr_TR
dc.contributor.orcid0000-0003-0995-5260tr_TR
dc.contributor.orcid0000-0001-8889-1933tr_TR
dc.contributor.researcheridABE-3033-2020tr_TR
dc.contributor.researcheridAAA-5384-2020tr_TR
dc.contributor.scopusid7005398015tr_TR
dc.contributor.scopusid55370489800tr_TR
dc.contributor.scopusid7004734943tr_TR
dc.date.accessioned2023-01-23T13:39:46Z
dc.date.available2023-01-23T13:39:46Z
dc.date.issued2007-01-26
dc.description.abstractPURPOSE: To evaluate the complications associated with the primary placement of a motility coupling post (MCP) in spherical porous polyethylene (PP) implants at the time of enucleation. DESIGN: Retrospective, interventional case series. METHODS: The records of all patients who had undergone primary enucleation and spherical PP implant with MCP insertion, and who were followed for at least six months were reviewed. The MCP was screwed to a wrapped implant to protrude 3 mm to 4 mm anteriorly. After placing the implant into the orbit, the extraocular muscles were sutured to the implant, and the Tenon capsule and conjunctiva were closed onto the MCP. When the MCP was not exposed spontaneously within two months after surgery, it was externalized with a conjunctival cut-down procedure. RESULTS: The study included 52 patients (29 male, 23 female; age range, three to 76 years). The MCP became exposed spontaneously in 10 patients (19%). In the early postoperative period, we recorded nine complications in seven patients (13%), which might be related to primary MCP placement. These included prominent MCP decentration associated with implant motility restriction (6%), preseptal cellulitis (4%), and conjunctival prolapsus (8%). An ocular prosthesis was fit successfully onto the MCP in 51 patients. During the late period, 22 complications occurred in 15 patients (29%), including excessive discharge (15%), MCP decentration (4%), implant exposure (6%), implant infection (2%), pyogenic granuloma (8%), conjunctival overgrowth over the MCP (2%), conjunctival discoloration (4%), and lax eyelid syndrome (2%). Mean follow-up time was 34 months (range, six to 68 months). CONCLUSIONS: Although MCP placement in the spherical PP implant during enucleation is a useful technique, it may be associated with complications such as MCP decentration, excessive discharge, exposure, and infection of the implant.en_US
dc.identifier.citationYazıcı, B. vd. (2007). "Complications of primary placement of motility post in porous polyethylene implants during enucleation". American Journal of Ophthalmology, 143(5), 828-834.en_US
dc.identifier.endpage834tr_TR
dc.identifier.issn00029394
dc.identifier.issue5tr_TR
dc.identifier.pubmed17362860tr_TR
dc.identifier.scopus2-s2.0-34247097088tr_TR
dc.identifier.startpage828tr_TR
dc.identifier.urihttps://doi.org/10.1016/j.ajo.2007.01.049
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0002939407001201
dc.identifier.urihttp://hdl.handle.net/11452/30619
dc.identifier.volume143tr_TR
dc.identifier.wos000246288800015tr_TR
dc.indexed.pubmedPubmeden_US
dc.indexed.scopusScopusen_US
dc.indexed.wosSCIEen_US
dc.language.isoenen_US
dc.publisherElsevier Scienceen_US
dc.relation.journalAmerican Journal of Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectOphthalmologyen_US
dc.subjectPeg placementen_US
dc.subjectHydroxyapatite orbital implanten_US
dc.subjectCoralline hydroxyapatiteen_US
dc.subjectAnophthalmic socketen_US
dc.subjectCoupling posten_US
dc.subjectExperienceen_US
dc.subjectEviscerationen_US
dc.subjectExposureen_US
dc.subjectPreventionen_US
dc.subjectSleeveen_US
dc.subject.emtreeEnucleationen_US
dc.subject.emtreePolyethyleneen_US
dc.subject.emtreeAdolescenten_US
dc.subject.emtreeAdulten_US
dc.subject.emtreeAgeden_US
dc.subject.emtreeArticleen_US
dc.subject.emtreeChilden_US
dc.subject.emtreeConjunctivaen_US
dc.subject.emtreeConjunctiva diseaseen_US
dc.subject.emtreeEyelid diseaseen_US
dc.subject.emtreePyogenic granulomaen_US
dc.subject.emtreeFemaleen_US
dc.subject.emtreeMedical recorden_US
dc.subject.emtreeFollow upen_US
dc.subject.emtreePriority journalen_US
dc.subject.emtreeHumanen_US
dc.subject.emtreeMajor clinical studyen_US
dc.subject.emtreeImplantationen_US
dc.subject.emtreeIntervention studyen_US
dc.subject.emtreeMaleen_US
dc.subject.emtreeRetrospective studyen_US
dc.subject.emtreeSurgical infectionen_US
dc.subject.emtreeSurgical patienten_US
dc.subject.scopusOrbit Implant; Evisceration; Artificial Eyeen_US
dc.subject.wosOphthalmologyen_US
dc.titleComplications of primary placement of motility post in porous polyethylene implants during enucleationen_US
dc.typeArticle
dc.wos.quartileQ1en_US

Files

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: