Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: Preliminary results with variant flip-angle mode
dc.contributor.author | Alǧin, Oktay | |
dc.contributor.author | Türkbey, Barış | |
dc.contributor.author | Özmen, Evrim | |
dc.contributor.author | Karaoǧlanoǧlu, Mustafa | |
dc.contributor.author | Arslan, Halil | |
dc.contributor.buuauthor | Ocakoğlu, Gökhan | |
dc.contributor.department | Uludağ Üniversitesi/Tıp Fakültesi/Biyoistatistik Anabilim Dalı. | tr_TR |
dc.contributor.researcherid | AAH-5180-2021 | tr_TR |
dc.contributor.scopusid | 15832295800 | tr_TR |
dc.date.accessioned | 2022-11-18T13:28:55Z | |
dc.date.available | 2022-11-18T13:28:55Z | |
dc.date.issued | 2013-03 | |
dc.description.abstract | Purpose: This prospective study aimed to evaluate the use of three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) in the diagnosis of spontaneous third ventriculostomy (STY) and to compare it with phase-contrast cine magnetic resonance imaging (PC-MRI). Methods: PC-MRI and 3D-SPACE images were obtained in 15 patients with hydrocephalus for evaluation of STY as well as in 10 control cases. The presence of STY was evaluated visually by two experienced radiologists on both PC-MRI and 3D-SPACE images, and the results were statistically compared. Results: There was a strong correlation between PC-MRI and SPACE scores for both readers (correlation coefficient [r] = 0.784; P = 0.001). There was also a good correlation between PC-MRI scores and consensus-based results. Interobserver reliabilities were strong for all STY scores. In addition, there was excellent correlation between 3D-SPACE scores and consensus-based results (first reader's kappa value: 0.87; second reader's kappa value: 1). Conclusion: 3D-SPACE can provide morphological physiological information for the evaluation of STY with no need for additional PC-MRI analysis or other sequences. As a non-invasive test, it can also be included among the first line of choices of MRI sequences for patients with obstructive hydrocephalus. | en_US |
dc.identifier.citation | Algin, O. vd. (2013). "Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: Preliminary results with variant flip-angle mode". Journal of Neuroradiology, 40(1), 11-18. | en_US |
dc.identifier.endpage | 18 | tr_TR |
dc.identifier.issn | 0150-9861 | |
dc.identifier.issue | 1 | tr_TR |
dc.identifier.pubmed | 22305437 | tr_TR |
dc.identifier.scopus | 2-s2.0-84875116692 | tr_TR |
dc.identifier.startpage | 11 | tr_TR |
dc.identifier.uri | https://doi.org/10.1016/j.neurad.2011.12.003 | |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0150986111001441 | |
dc.identifier.uri | http://hdl.handle.net/11452/29493 | |
dc.identifier.volume | 40 | tr_TR |
dc.identifier.wos | 000317092100002 | |
dc.indexed.pubmed | PubMed | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.indexed.wos | SCIE | en_US |
dc.language.iso | en | en_US |
dc.publisher | Journal of Neuroradiology | en_US |
dc.relation.collaboration | Yurt içi | tr_TR |
dc.relation.collaboration | Sanayi | tr_TR |
dc.relation.journal | Journal of Neuroradiology | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Neurosciences & neurology | en_US |
dc.subject | Radiology, nuclear medicine & medical imaging | en_US |
dc.subject | Spontaneous third ventriculostomy | en_US |
dc.subject | Obstructive hydrocephalus | en_US |
dc.subject | Magnetic resonance imaging | en_US |
dc.subject | 3D-space | en_US |
dc.subject | Phase-contrast cine MRI | en_US |
dc.subject | Single-slab | en_US |
dc.subject | Cisternography | en_US |
dc.subject | 3d-ciss | en_US |
dc.subject | Space | en_US |
dc.subject | 3D | en_US |
dc.subject.emtree | Adolescent | en_US |
dc.subject.emtree | Adult | en_US |
dc.subject.emtree | Aged | en_US |
dc.subject.emtree | Anastomosis | en_US |
dc.subject.emtree | Article | en_US |
dc.subject.emtree | Brain disease | en_US |
dc.subject.emtree | Child | en_US |
dc.subject.emtree | Cineradiography | en_US |
dc.subject.emtree | Clinical article | en_US |
dc.subject.emtree | Clinical examination | en_US |
dc.subject.emtree | Consensus | en_US |
dc.subject.emtree | Controlled clinical trial | en_US |
dc.subject.emtree | Controlled study | en_US |
dc.subject.emtree | Diagnostic value | en_US |
dc.subject.emtree | Female | en_US |
dc.subject.emtree | Human | en_US |
dc.subject.emtree | Image display | en_US |
dc.subject.emtree | Intermethod comparison | en_US |
dc.subject.emtree | Male | en_US |
dc.subject.emtree | Nuclear magnetic resonance imaging | en_US |
dc.subject.emtree | Nuclear magnetic resonance scanner | en_US |
dc.subject.emtree | Obstructive hydrocephalus | en_US |
dc.subject.emtree | Phase contrast cine magnetic resonance imaging | en_US |
dc.subject.emtree | Prospective study | en_US |
dc.subject.emtree | Radiologist | en_US |
dc.subject.emtree | Reliability | en_US |
dc.subject.emtree | Scoring system | en_US |
dc.subject.emtree | Spontaneous third ventriculostomy | en_US |
dc.subject.emtree | Three dimensional imaging | en_US |
dc.subject.emtree | Three dimensional sampling perfection with application optimized optimized contrasts using different flip angle evolution | en_US |
dc.subject.mesh | Adolescent | en_US |
dc.subject.mesh | Adult | en_US |
dc.subject.mesh | Aged | en_US |
dc.subject.mesh | Algorithms | en_US |
dc.subject.mesh | Child | en_US |
dc.subject.mesh | Female | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Hydrocephalus | en_US |
dc.subject.mesh | Image enhancement | en_US |
dc.subject.mesh | Image interpretation, computer-assisted | en_US |
dc.subject.mesh | Imaging, three-dimensional | en_US |
dc.subject.mesh | Magnetic resonance imaging | en_US |
dc.subject.mesh | Male | en_US |
dc.subject.mesh | Middle aged | en_US |
dc.subject.mesh | Pilot projects | en_US |
dc.subject.mesh | Reproducibility of results | en_US |
dc.subject.mesh | Sample size | en_US |
dc.subject.mesh | Sensitivity and specificity | en_US |
dc.subject.mesh | Surgery, computer-assisted | en_US |
dc.subject.mesh | Third ventricle | en_US |
dc.subject.mesh | Treatment outcome | en_US |
dc.subject.mesh | Ventriculostomy | en_US |
dc.subject.scopus | Ventriculostomy; Hydrocephalus; Neuroendoscopy | en_US |
dc.subject.wos | Clinical neurology | en_US |
dc.subject.wos | Neuroimaging | en_US |
dc.subject.wos | Radiology, nuclear medicine & medical imaging | en_US |
dc.title | Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: Preliminary results with variant flip-angle mode | en_US |
dc.type | Article | |
dc.wos.quartile | Q3 (Radiology, nuclear medicine & medical imaging) | en_US |
dc.wos.quartile | Q4 | en_US |
Files
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: