Evaluating the effectiveness of 2 different flow diverter stents based on the stagnation region formation in an aneurysm sac using lagrangian coherent structure
dc.contributor.author | Mutlu, Onur | |
dc.contributor.author | Olcay, Ali Bahadır | |
dc.contributor.buuauthor | Hakyemez, Bahattin | |
dc.contributor.buuauthor | Bilgin, Cem | |
dc.contributor.department | Uludağ Üniversitesi/Tıp Fakültesi/Radyoloji Anabilim Dalı. | tr_TR |
dc.contributor.orcid | 0000-0002-3425-0740 | tr_TR |
dc.contributor.researcherid | AAI-2318-2021 | tr_TR |
dc.contributor.researcherid | HHS-7433-2022 | tr_TR |
dc.contributor.scopusid | 57200617643 | tr_TR |
dc.contributor.scopusid | 6602527239 | tr_TR |
dc.date.accessioned | 2023-10-19T07:08:53Z | |
dc.date.available | 2023-10-19T07:08:53Z | |
dc.date.issued | 2019-07 | |
dc.description.abstract | BACKGROUND: Flow diverter stents are often used in the treatment of giant aneurysms at carotid arteries. Although these stents promise to decrease blood flow into the aneurysm sac, little is known about hemodynamics inside the aneurysm once the stent is planted into the aneurysm neck. To further explore this, computational fluid dynamics and Lagrangian coherent structure (LCS) techniques were used to evaluate the time evolution mechanism of stagnation regions inside an aneurysm. The purpose of this work is to provide a quantitative effectiveness comparison of 2 different flow diverter stents placed into the aneurysm neck based on their stagnation zone formations in the sac.METHODS: In numerical modeling, Womersley function, and fluidsolid interaction were defined as the 3 cardiac cycles for blood velocity and the aneurysm wall, respectively. Moreover, blood was accepted as a non-Newtonian fluid, and mean arterial blood pressure of the patient was entered into the computational domain to accurately mimic the hemodynamics inside the aneurysm sac accurately.RESULTS: The numerical analyses revealed that the use of a Fred-type stent in the aneurysm neck causes fluid flow zone formations yielding to sequenced stagnated regions. Time evolution of stagnation regions in an aneurysm sac was shown just after a flow diverter stent was employed at a patient's aneurysm neck. Furthermore, the stagnation field in the Fred stent-fitted aneurysm was nearly 4.8 times the stagnation area of the Surpass brand stent-attached aneurysm.CONCLUSIONS: Finite time Lyapunov exponent fields obtained from the LCS techniques demonstrated a good agreement with the patient's digital subtraction angiography images obtained just after treatment. | en_US |
dc.identifier.citation | Mutlu, O. vd. (2019). "Evaluating the effectiveness of 2 different flow diverter stents based on the stagnation region formation in an aneurysm sac using lagrangian coherent structure". World Neurosurgery, 127, E727-E737. | en_US |
dc.identifier.endpage | e737 | tr_TR |
dc.identifier.issn | 1878-8750 | |
dc.identifier.issn | 1878-8769 | |
dc.identifier.pubmed | 30951913 | tr_TR |
dc.identifier.scopus | 2-s2.0-85064933725 | tr_TR |
dc.identifier.startpage | e727 | tr_TR |
dc.identifier.uri | https://doi.org/10.1016/j.wneu.2019.03.255 | |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S1878875019309350 | |
dc.identifier.uri | http://hdl.handle.net/11452/34439 | |
dc.identifier.volume | 127 | tr_TR |
dc.identifier.wos | 000473128300091 | tr_TR |
dc.indexed.pubmed | PubMed | en_US |
dc.indexed.scopus | Scopus | en_US |
dc.indexed.wos | SCIE | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Science Inc | en_US |
dc.relation.collaboration | Yurt içi | tr_TR |
dc.relation.journal | World Neurosurgery | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | tr_TR |
dc.relation.tubitak | 117M491 | tr_TR |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Lagrangian coherent structure | en_US |
dc.subject | Computational fluid dynamics | en_US |
dc.subject | Flow diverter stent effectiveness | en_US |
dc.subject | Stagnated fluid flow zones | en_US |
dc.subject | Internal carotid-artery | en_US |
dc.subject | Newtonian blood-flow | en_US |
dc.subject | Intracranial aneurysms | en_US |
dc.subject | Endovascular treatment | en_US |
dc.subject | Cerebral aneurysm | en_US |
dc.subject | Follow-up | en_US |
dc.subject | Diversion | en_US |
dc.subject | Reconstruction | en_US |
dc.subject | Simulation | en_US |
dc.subject | Occlusion | en_US |
dc.subject | Clinical neurology | en_US |
dc.subject | Surgery | en_US |
dc.subject.emtree | Adult | en_US |
dc.subject.emtree | Article | en_US |
dc.subject.emtree | Blood clotting | en_US |
dc.subject.emtree | Blood flow velocity | en_US |
dc.subject.emtree | Case report | en_US |
dc.subject.emtree | Clinical article | en_US |
dc.subject.emtree | Comparative effectiveness | en_US |
dc.subject.emtree | Computational fluid dynamics | en_US |
dc.subject.emtree | Controlled study | en_US |
dc.subject.emtree | Digital imaging and communications in medicine | en_US |
dc.subject.emtree | Digital subtraction angiography | en_US |
dc.subject.emtree | Evaluation study | en_US |
dc.subject.emtree | Female | en_US |
dc.subject.emtree | Fluid flow | en_US |
dc.subject.emtree | Heart cycle | en_US |
dc.subject.emtree | Human | en_US |
dc.subject.emtree | Lagrangian coherent structure technique | en_US |
dc.subject.emtree | Mean arterial pressure | en_US |
dc.subject.emtree | Middle aged | en_US |
dc.subject.emtree | Neck | en_US |
dc.subject.emtree | Procedures | en_US |
dc.subject.emtree | Saccular aneurysm | en_US |
dc.subject.emtree | Brain circulation | en_US |
dc.subject.emtree | Diagnostic imaging | en_US |
dc.subject.emtree | Hemodynamics | en_US |
dc.subject.emtree | Hydrodynamics | en_US |
dc.subject.emtree | Intracranial aneurysm | en_US |
dc.subject.emtree | Physiology | en_US |
dc.subject.emtree | Self expandable metallic stent | en_US |
dc.subject.emtree | Treatment outcome | en_US |
dc.subject.mesh | Blood flow velocity | en_US |
dc.subject.mesh | Cerebrovascular circulation | en_US |
dc.subject.mesh | Female | en_US |
dc.subject.mesh | Hemodynamics | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Hydrodynamics | en_US |
dc.subject.mesh | Intracranial aneurysm | en_US |
dc.subject.mesh | Middle aged | en_US |
dc.subject.mesh | Self expandable metallic stents | en_US |
dc.subject.mesh | Treatment outcome | en_US |
dc.subject.scopus | Artificial Embolization; Diverters; Stents | en_US |
dc.subject.wos | Clinical neurology | en_US |
dc.subject.wos | Surgery | en_US |
dc.title | Evaluating the effectiveness of 2 different flow diverter stents based on the stagnation region formation in an aneurysm sac using lagrangian coherent structure | en_US |
dc.type | Article | |
dc.wos.quartile | Q3 | en_US |
Files
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: