Investigation of the effect of the roof geometry on building thermal behaviour

dc.contributor.authorYıldırım, Erdal
dc.contributor.authorFıratoğlu, Zeynel Abidin
dc.contributor.authorYeşilata, Bülent
dc.date.accessioned2020-08-17T05:59:05Z
dc.date.available2020-08-17T05:59:05Z
dc.date.issued2017-12-05
dc.description.abstractMain objective of this study is to investigate effect of the roof geometry on indoor air conditions in terms of energy efficiency in summer. Harran’s conical roofed building has for this purpose been compared with flat roofed building of equivalent thermo-physical properties, base area and volume. Three dimensional CFD simulations using the low-Reynolds number modeling (LRNM) and standard turbulence models are performed. The effect of roof geometry on natural ventilation is investigated. Cross ventilation flow rates and convection heat transfer coefficients for these two roof types are evaluated for this purpose. Cross ventilation flow rate for the house with conical roof is found to be 8% higher than that of the flat one. The result of the numerical analysis reveals as well that the conical roof transfers 30% less heat to interior side for a representative summer day, resulting in lower indoor air temperature in the house.
dc.description.abstractBu çalışmanın amacı yaz ayları için enerji verimliliği açısından, bina çatı geometrisinin iç ortam havasına etkisini araştırmaktır. Bu amaçla Harran konik çatılı yapıları aynı taban alanı, hacim ve termofiziksel özelliklere sahip düz çatılı bina ile karşılaştırılmıştır. Low-Reynolds Number modeling (LRNM) ve k-ε türbülans modeli kullanılarak üç boyutlu CFD simülasyonu gerçekleştirilmiştir. Çatı geometrisinin doğal havalandırmaya etkisi araştırılmıştır. Bu kapsamda çapraz havalandırma debisi ve taşınım ısı transfer katsayıları değerlendirilmiştir. Harran evi çapraz havalandırma açısından düz çatılı yapıya göre % 8 daha iyi performans göstermektedir. Sayısal analizler sonucundan tipik bir yaz günü için Harran evinin kubbesinin düz çatıdan % 30 daha az ısı atağına maruz kaldığı ve bunun daha düşük iç ortam havası sıcaklığına neden olduğu ortaya çıkmıştır.
dc.identifier.citationYıldırım, E. vd. (2017). "Investigation of the effect of the roof geometry on building thermal behaviour". Uludağ Üniversitesi Mühendislik Fakültesi Dergisi, 22(3), 187-200.
dc.identifier.endpage200
dc.identifier.issn2148-4147
dc.identifier.issn2148-4155
dc.identifier.issue3
dc.identifier.startpage187
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/400525
dc.identifier.urihttp://hdl.handle.net/11452/12264
dc.identifier.volume22
dc.language.isoen
dc.publisherUludağ Üniversitesi
dc.relation.journalUludağ Üniversitesi Mühendislik Dergisi / Uludağ University Journal of The Faculty of Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectHarran house
dc.subjectRoof geometry
dc.subjectThermal performance
dc.subjectNatural ventilation
dc.subjectConvection heat transfer coefficient
dc.subjectHarran evi
dc.subjectÇatı geometrisi
dc.subjectIsıl performans
dc.subjectDoğal havalandırma
dc.subjectTaşınım ısı transfer
dc.titleInvestigation of the effect of the roof geometry on building thermal behaviour
dc.title.alternativeÇatı geometrisin bina ısıl davranışı üzerindeki etkisinin incelenmesi
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
22_3_14.pdf
Size:
1.57 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: