Reference intervals comparison of calculation methods and evaluation of procedures for merging reference measurements fromTwo US medical centers

dc.contributor.authorKlee, George G.
dc.contributor.authorIchihara, Kiyoshi
dc.contributor.authorBaumann, Nikola A.
dc.contributor.authorStraseski, Joely A.
dc.contributor.authorBryant, Sandra C.
dc.contributor.authorWood, Christina M. Wentz
dc.contributor.buuauthorÖzarda, Yeşim
dc.contributor.departmentUludağ Üniversitesi/Tıp Fakültesi/Temel Tıp Bilimleri.tr_TR
dc.contributor.researcheridAAL-8873-2021tr_TR
dc.contributor.scopusid35741320500tr_TR
dc.date.accessioned2023-09-28T10:41:09Z
dc.date.available2023-09-28T10:41:09Z
dc.date.issued2018-12
dc.description.abstractObjectives: To analyze consistency of reference limits and widths of reference intervals (RIs) calculated by six procedures and evaluate a protocol for merging intrainstitutional reference data. Methods: The differences between reference limits were compared with "optimal" bias goals. Also, widths of the RIs were compared. RIs were calculated using Mayo-SAS quantile, EP Evaluator, and four International Federation of Clinical Chemistry and Laboratory Medicine methods: parametric and nonparametric (NP) with and without latent abnormal values exclusion (LAVE). Regression parameters from cotested samples were evaluated for harmonizing intrainstitutional reference data. Results: Mayo-SAS quintile, LAVE(-) NP, and EP Evaluator generated similar RIs, but these RIs often were wider than RIs from parametric procedures. LAVE procedures generated narrower RIs for nutritional and inflammatory markers. Transformation with regression parameters did not ensure homogeneity of merged data. Conclusions: Parametric methods are recommended when inappropriate values cannot be excluded. The nonparametric procedures may generate wider RIs. Data sets larger than 200 are recommended for robust estimates. Caution should be exercised when merging intrainstitutional data.en_US
dc.identifier.citationKlee, G.G. vd. (2018). ''Reference intervals comparison of calculation methods and evaluation of procedures for merging reference measurements fromTwo US medical centers''. American Journal of Clinical Pathology, 150(6), 545-554.en_US
dc.identifier.endpage554tr_TR
dc.identifier.issn0002-9173
dc.identifier.issn1943-7722
dc.identifier.issue6tr_TR
dc.identifier.pubmed30169553tr_TR
dc.identifier.scopus2-s2.0-85055595174tr_TR
dc.identifier.startpage545tr_TR
dc.identifier.urihttps://doi.org/10.1093/AJCP/AQY082
dc.identifier.urihttps://academic.oup.com/ajcp/article/150/6/545/5087951?login=true
dc.identifier.urihttp://hdl.handle.net/11452/34131
dc.identifier.volume150tr_TR
dc.identifier.wos000456564300009tr_TR
dc.indexed.scopusScopusen_US
dc.indexed.wosSCIEen_US
dc.language.isoenen_US
dc.publisherOxford Universityen_US
dc.relation.collaborationYurt dışıtr_TR
dc.relation.journalAmerican Journal of Clinical Pathologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergitr_TR
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectPathologyen_US
dc.subjectReference valuesen_US
dc.subjectNormal valuesen_US
dc.subjectMerging reference dataen_US
dc.subjectMethod comparisonen_US
dc.subjectSerum panelen_US
dc.subjectParametric methoden_US
dc.subjectNonparametric methoden_US
dc.subjectBox-cox power transformationen_US
dc.subjectLatent abnormal values exclusion (LAVE)en_US
dc.subjectGlobal multicenteren_US
dc.subjectWorldwide multicenteren_US
dc.subjectDerivationen_US
dc.subjectPanelen_US
dc.subject.emtreeAbnormal valueen_US
dc.subject.emtreeArticleen_US
dc.subject.emtreeCalculationen_US
dc.subject.emtreeClinical chemistryen_US
dc.subject.emtreeIntermethod comparisonen_US
dc.subject.emtreeNormal valueen_US
dc.subject.emtreeComparative studyen_US
dc.subject.emtreeHumanen_US
dc.subject.emtreeLaboratory techniqueen_US
dc.subject.emtreeReference valueen_US
dc.subject.emtreeStandardsen_US
dc.subject.meshClinical laboratory techniquesen_US
dc.subject.meshHumansen_US
dc.subject.meshReference valuesen_US
dc.subject.scopusClinical Chemistry; Thyrotropin; Chemical Speciesen_US
dc.subject.wosPathologyen_US
dc.titleReference intervals comparison of calculation methods and evaluation of procedures for merging reference measurements fromTwo US medical centersen_US
dc.typeArticle
dc.wos.quartileQ2en_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Özarda_vd_2018.pdf
Size:
1.98 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: