Publication: Surface characteristics and wettability of novel gingival col designed 3-d printed dental sectional matrices
dc.contributor.author | Çelik, Halil | |
dc.contributor.buuauthor | Çelik, Zeynep Ceren | |
dc.contributor.buuauthor | ÇELİK, ZEYNEP CEREN | |
dc.contributor.buuauthor | Elbek Çubukçu, Çiğdem | |
dc.contributor.buuauthor | ELBEK ÇUBUKÇU, ÇİĞDEM | |
dc.contributor.department | Bursa Uludağ Üniversitesi/Diş Hekimliği Fakültesi/Periondontoloji Anabilim Dalı. | |
dc.contributor.orcid | 0000-0002-6900-2632 | |
dc.date.accessioned | 2024-09-13T12:25:40Z | |
dc.date.available | 2024-09-13T12:25:40Z | |
dc.date.issued | 2023-07-28 | |
dc.description.abstract | Objective: The physical properties and wettability of 3-D printed Polyethylene terephthalate - glycol (PET-G) and Poly(lactic) acid (PLA) dental sectional matrices were investigated.Methods: Experimental matrices was designed in a rectangular shape one-side depression corresponds to gingival col and without sharp edges and printed on FDM machine Ender Pro 3 (Creality((R)), Shenzhen, China). The physical textures, thicknesses, water contact angles were compared to conventional stainless steel (SS) matrix.Results: PETG and PLA sample matrices were clinically single-side smooth compared to SS matrix. PETG specimens had uniformly 0.055 mm whereas PLAs were non-uniformly similar to 0.065-0.075 mm in thickness. The mean +/- standard deviation (SS) of contact angle for SS was 78.29 +/- 0.18, for PETG was 72.09 +/- 0.94, for PLA was 73.03 +/- 1.17.Conclusion: PETG and PLA dental matrices might have desirable properties: being hydrophobic, non-charged, easy to manufacture and mimicking the gingival col depression in the dental interproximal contact area. | |
dc.identifier.doi | 10.1515/bmt-2023-0229 | |
dc.identifier.endpage | 15 | |
dc.identifier.issn | 0013-5585 | |
dc.identifier.issue | 1 | |
dc.identifier.startpage | 11 | |
dc.identifier.uri | https://doi.org/10.1515/bmt-2023-0229 | |
dc.identifier.uri | https://hdl.handle.net/11452/44726 | |
dc.identifier.volume | 69 | |
dc.identifier.wos | 001038272200001 | |
dc.indexed.wos | WOS.SCI | |
dc.language.iso | en | |
dc.publisher | Walter De Gruyter Gmbh | |
dc.relation.journal | Biomedical Engineering-biomedizinische Technik | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.subject | 3-d printing | |
dc.subject | Matrix bands | |
dc.subject | Poly(lactic) acid | |
dc.subject | Polyethylene terephthalate-glycol | |
dc.subject | Wettability | |
dc.subject | Science & technology | |
dc.subject | Technology | |
dc.subject | Life sciences & biomedicine | |
dc.subject | Engineering, biomedical | |
dc.subject | Medical informatics | |
dc.subject | Engineering | |
dc.title | Surface characteristics and wettability of novel gingival col designed 3-d printed dental sectional matrices | |
dc.type | Article | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 961fc58a-0ee1-4e59-8140-d3453a9bd712 | |
relation.isAuthorOfPublication | 80c78b97-5030-4025-9f5d-09d971582915 | |
relation.isAuthorOfPublication.latestForDiscovery | 961fc58a-0ee1-4e59-8140-d3453a9bd712 |