Calculation of annual energy requirement of existing constructions and improvement suggestions for building envelope: An educational structure example

dc.contributor.authorBeytekin, Hatice Elif Arslan
dc.contributor.authorSezer, Filiz Şenkal
dc.contributor.buuauthorBeytekin, Hatice Elif Arslan
dc.contributor.buuauthorŞENKAL SEZER, FİLİZ
dc.contributor.departmentUludağ Üniversitesi/Mimarlık Fakültesi
dc.contributor.orcid0000-0002-1204-6028
dc.contributor.researcheridKXR-6736-2024
dc.contributor.researcheridQ-3337-2017
dc.date.accessioned2024-10-04T11:33:40Z
dc.date.available2024-10-04T11:33:40Z
dc.date.issued2017-01-01
dc.description.abstractThe energy problem is becoming increasingly important all over the world due to its environmental and economic dimensions. Due to their high energy needs, buildings have a significant share in total energy consumption. For this reason, the design of environmentally friendly structures that use energy efficiently or the conversion of existing structures into energy efficient structures has become a priority in the policies of many countries today. In this study, using the Design Builder program, one of the international energy simulation programs that measure energy efficiency, the total annual energy requirement of an existing building selected as an example to be taken into consideration for the current application project, has been calculated. In addition, the building is divided into, and the energy needs are calculated separately for heating, cooling, electrical equipment and lighting by zone. Two different suggestions have been presented for the improvement of the building envelope in line with these results. One of the proposals was made by taking into consideration the TS 825 Thermal Insulation Regulation, valid in Turkey. In the 2nd suggestion, a general approach was taken, determining the zones where the energy needs are highest per unit area, and a building envelope suggestion providing the balancing of the energy needs for these zones to the general needs of the building has been developed.
dc.identifier.doi10.14207/ejsd.2017.v6n3p51
dc.identifier.eissn2239-6101
dc.identifier.endpage60
dc.identifier.issn2239-5938
dc.identifier.issue3
dc.identifier.startpage51
dc.identifier.urihttps://doi.org/10.14207/ejsd.2017.v6n3p51
dc.identifier.urihttps://ecsdev.org/ojs/index.php/ejsd/article/view/499/496
dc.identifier.urihttps://hdl.handle.net/11452/45881
dc.identifier.volume6
dc.identifier.wos000412135600006
dc.indexed.wosWOS.ESCI
dc.language.isoen
dc.publisherEuropean Center Sustainable Development
dc.relation.journalEuropean Journal of Sustainable Development
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEnergy efficiency
dc.subjectBuilding envelope
dc.subjectDesign builder
dc.subjectScience & technology
dc.subjectLife sciences & biomedicine
dc.subjectEnvironmental sciences
dc.titleCalculation of annual energy requirement of existing constructions and improvement suggestions for building envelope: An educational structure example
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublicationf8aa6033-87aa-4288-b33f-2ef54ff23690
relation.isAuthorOfPublication.latestForDiscoveryf8aa6033-87aa-4288-b33f-2ef54ff23690

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Beytekin_Sezer_2017.pdf
Size:
619.92 KB
Format:
Adobe Portable Document Format

Collections