Publication:
Evaluation of energy resolution by changing angle and position of incident photon in a lyso calorimeter

dc.contributor.authorSaad, A. M. E.
dc.contributor.authorKoçak, Fatma
dc.contributor.buuauthorKOÇAK, FATMA
dc.contributor.buuauthorSaad, Ahmed Mohamed Elfatih
dc.contributor.departmentBursa Uludağ Üniversitesi/Fen-Edebiyat Fakültesi/Fizik Bölümü
dc.contributor.orcid0000-0002-4756-9988
dc.contributor.researcheridJZE-5260-2024
dc.contributor.researcheridAAE-3350-2022
dc.date.accessioned2024-07-02T11:16:45Z
dc.date.available2024-07-02T11:16:45Z
dc.date.issued2020-01-01
dc.description.abstractIn this paper, we investigate the effect on energy resolution from changing the angle and the position of incidence photon for a 5 x 5 crystal matrix built with (25 x 25 x 200) mm(3) LYSO scintillating crystals. Those crystals have been proposed for the electromagnetic calorimeter of the Turkish Accelerator Center-Particle Factory (TAC-PF) detector. The energy resolution was obtained as sigma(E)/E = 0.42%/ root E/GeV circle plus 1.60% at the center of the matrix in the energy range of 50 MeV to 2 GeV. When we examined the dependence of the energy resolution on the incidence angle of the photon, resolution began to deteriorate at angles greater than 2 degrees on the 5 x 5 crystal matrix. Moreover, energy resolution at the corners of the central crystal was worse than at the center of the central crystal by a factor of 1.3 at 50 MeV and 1.1 at 2 GeV.
dc.identifier.doi10.5506/APhysPolB.51.2097
dc.identifier.eissn1509-5770
dc.identifier.issn0587-4254
dc.identifier.issue11
dc.identifier.urihttps://doi.org/10.5506/APhysPolB.51.2097
dc.identifier.urihttps://www.actaphys.uj.edu.pl/index_n.php?I=R&V=51&N=11#2097
dc.identifier.urihttps://hdl.handle.net/11452/42743
dc.identifier.volume51
dc.identifier.wos000591879200007
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherJagiellonian Univ Press
dc.relation.journalActa Physica Polonica B
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCrystal
dc.subjectSimulation
dc.subjectScience & technology
dc.subjectPhysical sciences
dc.subjectPhysics, multidisciplinary
dc.subjectPhysics
dc.titleEvaluation of energy resolution by changing angle and position of incident photon in a lyso calorimeter
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublication41e48773-f83c-49a1-a908-b303e75a52e4
relation.isAuthorOfPublication.latestForDiscovery41e48773-f83c-49a1-a908-b303e75a52e4

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Saad_ve_Koçak_2020.pdf
Size:
1.22 MB
Format:
Adobe Portable Document Format

Collections