Publication: Rare use of twin solitaire® stents in the double waffle-cone technique for endovascular treatment of a wide-necked bifurcation aneurysm
dc.contributor.author | Nas, Ömer Fatih | |
dc.contributor.author | Kaçar, Emre | |
dc.contributor.author | Kaya, Ahmet | |
dc.contributor.author | Erdoğan, Cüneyt | |
dc.contributor.author | Hakyemez, Bahattin | |
dc.contributor.buuauthor | NAS, ÖMER FATİH | |
dc.contributor.buuauthor | KAYA, AHMET TUFAN | |
dc.contributor.buuauthor | Erdoğan, Cüneyt | |
dc.contributor.buuauthor | HAKYEMEZ, BAHATTİN | |
dc.contributor.department | Uludağ Üniversitesi/Tıp Fakültesi/Radyoloji Anabilim Dalı | |
dc.contributor.orcid | 0000-0002-8813-6513 | |
dc.contributor.orcid | 0000-0002-3425-0740 | |
dc.contributor.researcherid | AAI-2318-2021 | |
dc.contributor.researcherid | AAS-5392-2021 | |
dc.contributor.researcherid | AAG-8561-2021 | |
dc.contributor.researcherid | COE-1124-2022 | |
dc.date.accessioned | 2024-08-06T07:42:19Z | |
dc.date.available | 2024-08-06T07:42:19Z | |
dc.date.issued | 2015-04-01 | |
dc.description.abstract | Endovascular treatment of wide-necked bifurcation aneurysms may be challenging. The waffle-cone technique can be used in these aneurysms in case of acute angulation between parent artery and distal artery of the aneurysm. Solitaire (R) stent (Ev3, Irvine, CA, USA) has the significant advantage of mitigating the potential complication risks. This study reports the second case in the literature in which endovascular treatment of a wide-necked bifurcation aneurysm with the double waffle-cone technique by using twin Solitaire (R) stents proved to be successful. | |
dc.identifier.doi | 10.1177/1591019915581998 | |
dc.identifier.eissn | 2385-2011 | |
dc.identifier.endpage | 170 | |
dc.identifier.issn | 1591-0199 | |
dc.identifier.issue | 2 | |
dc.identifier.startpage | 167 | |
dc.identifier.uri | https://doi.org/10.1177/1591019915581998 | |
dc.identifier.uri | https://journals.sagepub.com/doi/10.1177/1591019915581998 | |
dc.identifier.uri | https://europepmc.org/article/PMC/4757251 | |
dc.identifier.uri | https://hdl.handle.net/11452/43743 | |
dc.identifier.volume | 21 | |
dc.identifier.wos | 000355259600004 | |
dc.indexed.wos | WOS.SCI | |
dc.language.iso | en | |
dc.publisher | Sage | |
dc.relation.journal | Interventional Neuroradiology | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Cerebral aneurysms | |
dc.subject | Complex | |
dc.subject | Device | |
dc.subject | Double waffle-cone technique | |
dc.subject | Solitaire (R) stent | |
dc.subject | Wide-necked bifurcation aneurysm | |
dc.subject | Acute angle | |
dc.subject | Science & technology | |
dc.subject | Life sciences & biomedicine | |
dc.subject | Clinical neurology | |
dc.subject | Radiology, nuclear medicine & medical imaging | |
dc.subject | Neurosciences & neurology | |
dc.title | Rare use of twin solitaire® stents in the double waffle-cone technique for endovascular treatment of a wide-necked bifurcation aneurysm | |
dc.type | Article | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 2aa7fdf5-f110-441f-b7ea-0d829a69f47b | |
relation.isAuthorOfPublication | 781db595-1829-4fcd-9774-7b9e63cfbff3 | |
relation.isAuthorOfPublication | 9ad8c0f1-5154-4a82-b029-77c58cb35066 | |
relation.isAuthorOfPublication.latestForDiscovery | 2aa7fdf5-f110-441f-b7ea-0d829a69f47b |
Files
Original bundle
1 - 1 of 1