Publication:
Timing performance of a micro-channel-plate photomultiplier tube

dc.contributor.authorBortfeldt, J.
dc.contributor.authorBrunbauer, F.
dc.contributor.authorDavid, C.
dc.contributor.authorDesforge, D.
dc.contributor.authorFanourakis, G.
dc.contributor.authorGallinaro, M.
dc.contributor.authorGarcia, F.
dc.contributor.authorGiomataris, I
dc.contributor.authorGustavsson, T.
dc.contributor.authorGuyot, C.
dc.contributor.authorIguaz, F. J.
dc.contributor.authorKebbiri, M.
dc.contributor.authorKordas, K.
dc.contributor.authorLegou, P.
dc.contributor.authorLiu, J.
dc.contributor.authorLupberger, M.
dc.contributor.authorManthos, I
dc.contributor.authorMueller, H.
dc.contributor.authorNiaouris, V
dc.contributor.authorOliveri, E.
dc.contributor.authorPapaevangelou, T.
dc.contributor.authorParaschou, K.
dc.contributor.authorPomorski, M.
dc.contributor.authorResnati, F.
dc.contributor.authorRopelewski, L.
dc.contributor.authorSampsonidis, D.
dc.contributor.authorSchneider, T.
dc.contributor.authorSchwemling, P.
dc.contributor.authorScorsone, E.
dc.contributor.authorSohl, L.
dc.contributor.authorvan Stenis, M.
dc.contributor.authorThuiner, P.
dc.contributor.authorTsipolitis, Y.
dc.contributor.authorTzamarias, S. E.
dc.contributor.authorVeenhof, R.
dc.contributor.authorWang, X.
dc.contributor.authorWhite, S.
dc.contributor.authorZhang, Z.
dc.contributor.authorZhou, Y.
dc.contributor.buuauthorVeenhof, Rob
dc.contributor.departmentBursa Uludağ Üniversitesi/Fen-Edebiyat Fakültesi/Fizik Bölümü
dc.contributor.researcheridGJK-8031-2022
dc.date.accessioned2024-07-23T11:56:21Z
dc.date.available2024-07-23T11:56:21Z
dc.date.issued2020-04-21
dc.description.abstractThe spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r<5.5 mm) the time resolution of the two MCP-PMTS combined is better than 10 ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial dependence is in quantitative agreement with a dedicated simulation. With this characterization, the suitability of MCP-PMTS as t(0) reference detectors has been validated.
dc.description.sponsorshipCross-Disciplinary Program on Instrumentation and Detection of CEA, the French Alternative Energies and Atomic Energy Commission
dc.description.sponsorshipRD51 collaboration
dc.description.sponsorshipFundamental Research Funds for the Central Universities
dc.description.sponsorshipAppeared in source as:Fundamental Research Funds for the Central Universities of China
dc.description.sponsorshipPHENIICS Doctoral School Program of Universite Paris-Saclay
dc.description.sponsorshipCOFUND-FP-CERN-2014 program - 665779
dc.description.sponsorshipFundacao para a Ciencia e a Tecnologia (FCT) - IF/00410/2012 - CERN/FISPAR/0006/2017
dc.description.sponsorshipEnhanced Eurotalents program - PCOFUND-GA-2013-600382
dc.description.sponsorshipUS CMS program under DOE contract - DE-AC02-07CH11359
dc.identifier.doi10.1016/j.nima.2020.163592
dc.identifier.eissn1872-9576
dc.identifier.issn0168-9002
dc.identifier.urihttps://doi.org/10.1016/j.nima.2020.163592
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0168900220301613?via%3Dihub
dc.identifier.urihttps://hal.science/hal-02393388/document
dc.identifier.urihttps://hdl.handle.net/11452/43387
dc.identifier.volume960
dc.identifier.wos000518527200021
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherElsevier
dc.relation.journalNuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors And Associated Equipment
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectResolution
dc.subjectMcp-pmt
dc.subjectTime resolution
dc.subjectCherenkov light
dc.subjectBeam test
dc.subjectT0-reference
dc.subjectMonte-carlo simulation
dc.subjectScience & technology
dc.subjectTechnology
dc.subjectPhysical sciences
dc.subjectInstruments & instrumentation
dc.subjectNuclear science & technology
dc.subjectPhysics, nuclear
dc.subjectPhysics, particles & fields
dc.subjectInstruments & instrumentation
dc.subjectNuclear science & technology
dc.subjectPhysics
dc.titleTiming performance of a micro-channel-plate photomultiplier tube
dc.typeArticle
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Veenhof_vd_2020.pdf
Size:
983.5 KB
Format:
Adobe Portable Document Format

Collections