Publication:
Effects of separation space diameter on the performance of a novel reverse flow cyclone

dc.contributor.authorSakin, Ali
dc.contributor.authorKaragöz, İrfan
dc.contributor.authorAvcı, Atakan
dc.contributor.buuauthorKARAGÖZ, İRFAN
dc.contributor.buuauthorAVCI, ATAKAN
dc.contributor.departmentUludağ Üniversitesi/Mühendislik Fakültesi/Makine Mühendisliği Bölümü
dc.contributor.orcid0000-0002-7442-2746
dc.contributor.researcheridAAB-9388-2020
dc.date.accessioned2024-09-11T09:49:30Z
dc.date.available2024-09-11T09:49:30Z
dc.date.issued2019-10-13
dc.description.abstractA numerical study was carried out to investigate the effect of separation space diameter on the performance of a novel reverse flow tangential inlet cyclone design by using the Eulerian-Lagrangian approach. The design of this cyclone is based on the idea of increasing vortex length and decreasing pressure drop compared with traditional cyclones. This novel cyclone differs from the traditional cyclones with separation space and vortex limiter instead of the conical part. A qualitative numerical study was performed to analyze the effect of separation space diameter on the cyclone performance at different flow rates by evaluating velocity profile, pressure drop, fractional and overall efficiencies. The results show that the collection efficiency of smaller particles increases while pressure drop decreases significantly with the increase in separation space diameter for D-1/D < 0.5.
dc.identifier.doi10.1080/01496395.2018.1547314
dc.identifier.endpage2460
dc.identifier.issn0149-6395
dc.identifier.issue15
dc.identifier.startpage2450
dc.identifier.urihttps://doi.org/10.1080/01496395.2018.1547314
dc.identifier.urihttps://www.tandfonline.com/doi/full/10.1080/01496395.2018.1547314
dc.identifier.urihttps://hdl.handle.net/11452/44557
dc.identifier.volume54
dc.identifier.wos000482078600010
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherTaylor
dc.relation.journalSeparation Science and Technology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.relation.tubitak114M591
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectPressure-drop
dc.subjectDimensions
dc.subjectTwo phase flow
dc.subjectSeparation efficiency
dc.subjectPressure drop
dc.subjectCfd
dc.subjectEulerian-lagrangian
dc.subjectScience & technology
dc.subjectPhysical sciences
dc.subjectTechnology
dc.subjectChemistry, multidisciplinary
dc.subjectEngineering, chemical
dc.subjectChemistry
dc.subjectEngineering
dc.titleEffects of separation space diameter on the performance of a novel reverse flow cyclone