dc.description.abstractIn this study, the performance of a case study of Organic Rankine Cycle with heat recovery exchanger using different fluids is analyzed. As the fluids worked in the cycle, the commonly used R134a, R236fa, R245fa, R600a, R717 and R718 are preferred. Cycle performances of the selected fluids are compared based on both the heat source's temperature that changes between 80 degrees C and 109 degrees C and the effectiveness of the heat exchanger. Furthermore, the contribution ratios and the order of importance of the parameters affecting the performance of the cycle are evaluated using the Taguchi statistical method. As a result, the effect of the waste-heat source temperature on the performance of the system is greater than the other parameters examined, and the contribution ratio of this parameter is determined as 59.80%. However, effectiveness of heat exchanger is found to be the least effective parameter and the effect ratio is calculated as 2.18%. In addition, the best and worst operating conditions are determined from the statistical analysis, and in these conditions, the thermal efficiencies of the Organic Rankine Cycle are obtained as 15.26% and 8.61%, respectively.
dc.identifier.endpage135
dc.identifier.issn1300-3615
dc.identifier.issue2
dc.identifier.startpage121
dc.identifier.urihttps://hdl.handle.net/11452/44635
dc.identifier.volume39
dc.identifier.wos000490849000003
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherTurkish Soc Thermal Sciences Technology
dc.relation.journalIsi Bilimi Ve Teknigi Dergisi-journal Of Thermal Science And Technology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectWorking fluids
dc.subjectOptimization
dc.subjectTemperature
dc.subjectOrc
dc.subjectDesign
dc.subjectSystem
dc.subjectPower
dc.subjectEfficiency
dc.subjectSelection
dc.subjectOrganic rankine cycle
dc.subjectWorking fluids
dc.subjectPerformance analysis
dc.subjectHeat exchanger
dc.subjectThermal efficiency
dc.subjectTaguchi method
dc.subjectScience & technology
dc.subjectPhysical sciences
dc.subjectTechnology
dc.subjectThermodynamics
dc.subjectEngineering, mechanical
dc.subjectEngineering
dc.titleA parametric analysis of the performance of organic rankine cycle with heat recovery exchanger and its statistical evaluation
dc.typeArticle
dspace.entity.typePublication
local.contributor.departmentMühendislik Fakültesi/Makine Mühendisliği Bölümü
relation.isAuthorOfPublication141ef710-f81e-4eef-8f2a-720d18a92185
relation.isAuthorOfPublication505e9209-8215-40f7-aaa6-8f5171aa6445
relation.isAuthorOfPublication403cb5d9-5eeb-4c66-a8cd-02c88fa3b7b7
relation.isAuthorOfPublication.latestForDiscovery141ef710-f81e-4eef-8f2a-720d18a92185

Files

Collections