Publication:
Parotid duct repair by use of an embolectomy catheter with a microvascular clamp

dc.contributor.buuauthorEtöz, Abdullah
dc.contributor.buuauthorTuncel, Umut
dc.contributor.buuauthorÖzcan, Murat
dc.contributor.departmentTıp Fakültesi
dc.contributor.departmentPlastik ve Rekonstrüktif Cerrahi Ana Bilim Dalı
dc.contributor.orcid0000-0001-5029-2927
dc.contributor.researcheridP-3185-2015
dc.contributor.scopusid6602256586
dc.contributor.scopusid6602652531
dc.contributor.scopusid7102067678
dc.date.accessioned2021-12-30T11:49:19Z
dc.date.available2021-12-30T11:49:19Z
dc.date.issued2006-01
dc.description.abstractParotid duct injuries represent a small percentage of overall facial trauma. It is reported that they are not thoroughly inspected, so that a high number of parotid duct injuries are undiagnosed.1 Awareness of such an injury can help avoid serious complications, some of which are difficult to treat. Also, trauma to the parotid duct usually involves adjacent structures, especially the facial nerve. Surgical exploration is necessary but not adequate for clarifying the existence of parotid duct injury alone. Balloon angioplasty catheters, polyethylene, and intravenous catheters are used to identify and cannulate the parotid duct after injury.2–4 An embolectomy catheter is described for use as a guide for parotid duct examination and repair. It can also be used as a temporary intraduct stent during the postoperative period.
dc.identifier.citationEtöz, A. vd. (2006). ''Parotid duct repair by use of an embolectomy catheter with a microvascular clamp''. Plastic and Reconstructive Surgery, 117(1), 330-331.
dc.identifier.endpage331
dc.identifier.issn0032-1052
dc.identifier.issue1
dc.identifier.pubmed16404303
dc.identifier.scopus2-s2.0-33644858475
dc.identifier.startpage330
dc.identifier.urihttps://doi.org/10.1097/01.prs.0000196232.60775.e4
dc.identifier.urihttps://journals.lww.com/plasreconsurg/Fulltext/2006/01000/Parotid_Duct_Repair_by_Use_of_an_Embolectomy.67.aspx
dc.identifier.urihttp://hdl.handle.net/11452/23768
dc.identifier.volume117
dc.identifier.wos000234439600063
dc.indexed.wosSCIE
dc.language.isoen
dc.publisherLippincott Williams
dc.relation.journalPlastic and Reconstructive Surgery
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectSurgery
dc.subjectEmbolectomy
dc.subjectParotid duct
dc.subjectCatheterization
dc.subjectFace injury
dc.subjectHuman
dc.subject.emtreePolyethylene
dc.subject.emtreeParotid gland
dc.subject.emtreeLigation
dc.subject.emtreeLaceration
dc.subject.emtreeInjury
dc.subject.emtreeHuman
dc.subject.emtreeFace injury
dc.subject.emtreeCatheterization
dc.subject.emtreeSurgical technique
dc.subject.emtreeStent
dc.subject.emtreePriority journal
dc.subject.emtreePostoperative period
dc.subject.emtreeParotid gland disease
dc.subject.emtreeMicrovascular surgery
dc.subject.emtreeLetter
dc.subject.emtreeFacial nerve
dc.subject.emtreeFace injury
dc.subject.emtreeEmbolectomy
dc.subject.emtreeCatheter
dc.subject.emtreeCannulation
dc.subject.meshParotid gland
dc.subject.meshLacerations
dc.subject.meshHumans
dc.subject.meshFacial injuries
dc.subject.meshConstriction
dc.subject.meshCatheterization
dc.subject.scopusSialolithiasis; Juvenile Recurrent Parotitis; Sialadenitis
dc.subject.wosSurgery
dc.titleParotid duct repair by use of an embolectomy catheter with a microvascular clamp
dc.typeEditorial Material
dc.wos.quartileQ2
dspace.entity.typePublication
local.contributor.departmentTıp Fakültesi/Plastik ve Rekonstrüktif Cerrahi Ana Bilim Dalı
local.indexed.atScopus
local.indexed.atWOS

Files

License bundle

Now showing 1 - 1 of 1
Placeholder
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: