Publication:
The calculation of self-shielding correction factors for large samples in ²⁴¹Am-Be isotopic neutron source

dc.contributor.authorAkkaya, Gizem
dc.contributor.buuauthorAKKAYA, GİZEM
dc.contributor.departmentBursa Uludağ Üniversitesi/Fen-Edebiyat Fakültesi/Fizik Bölümü.
dc.contributor.researcheridAAH-8784-2021
dc.date.accessioned2024-06-11T07:04:19Z
dc.date.available2024-06-11T07:04:19Z
dc.date.issued2021-10-19
dc.description.abstractIn the present study, it is aimed to calculate neutron self-shielding correction factors for cylinder sample geometry using different methods in the literature in the application of k(0)-NAA standardization method with Am-241-Be isotopic neutron source. These correction factors are important in calculating the accurate concentration values for large samples with a high neutron absorption cross-section in the application of the k(0)-NAA method. In order to see the validity of the applied theoretical and experimental methods, the obtained concentration values are given comparatively with respect to the known Mn concentrations. The mean concentration difference ranges from-3.4% to-9.7%. The thermal neutron self-shielding correction depends on all elements in the sample that absorb thermal neutrons. In k(0)-NAA applications with large samples, although timeconsuming, it is recommended to use the experimental methods after calculating the necessary parameters with the help of samples with known composition.
dc.identifier.doi10.1016/j.apradiso.2021.109990
dc.identifier.eissn1872-9800
dc.identifier.issn0969-8043
dc.identifier.urihttps://doi.org/10.1016/j.apradiso.2021.109990
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0969804321003869
dc.identifier.urihttps://hdl.handle.net/11452/41964
dc.identifier.volume179
dc.identifier.wos000718045400002
dc.indexed.wosWOS.SCI
dc.language.isoen
dc.publisherPergamon-Elsevier
dc.relation.journalApplied Radiation and Isotopes
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.relation.tubitakBIDEB-2218
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectActivation analysis
dc.subjectStandardization method
dc.subjectUniversal curve
dc.subjectNaa
dc.subjectSize
dc.subjectK(0)-naa standardization method
dc.subjectNeutron self-shielding correction factors
dc.subjectAm-be isotopic neutron source
dc.subjectChemistry
dc.subjectNuclear science & technology
dc.subjectRadiology, nuclear medicine & medical imaging
dc.titleThe calculation of self-shielding correction factors for large samples in ²⁴¹Am-Be isotopic neutron source