Publication:
Comparison of patient satisfaction rates for the malleable and two piece-inflatable penile prostheses

dc.contributor.authorKılıçarslan, Hakan
dc.contributor.authorKaynak, Yurdaer
dc.contributor.authorGökçen, Kaan
dc.contributor.authorCoşkun, Burhan
dc.contributor.authorKaygısız, Onur
dc.contributor.buuauthorKILIÇARSLAN, HAKAN
dc.contributor.buuauthorCOŞKUN, BURHAN
dc.contributor.buuauthorKAYGISIZ, ONUR
dc.contributor.departmentUludağ Üniversitesi/Tıp Fakültesi/Üroloji Anabilim Dalı.
dc.contributor.orcid0000-0002-9790-7295
dc.contributor.researcheridJIT-9412-2023
dc.contributor.researcheridAAH-9704-2021
dc.contributor.researcheridAAM-9726-2020
dc.date.accessioned2024-10-16T11:35:12Z
dc.date.available2024-10-16T11:35:12Z
dc.date.issued2014-12-01
dc.description.abstractObjective: To compare patient/partner satisfaction with AMS 600-650 and AMS Ambicore penile implants (American Medical Systems, Minneapolis, USA) in patients with erectile dysfunction.Material and methods: The modified Erectile Dysfunction Inventory of Treatment Satisfaction (EDITS) questionnaires at six months after implantation of 46 patients who underwent AMS 600-650 (n=23) or Ambicore placement (n=23) between 1/1/2008 and 1/1/2013 were analyzed.Results: The percentages of patients with AMS 600-650 who reported to be satisfied, very satisfied and neither satisfied nor dissatisfied with their prostheses were 34.78% (n=8), 30.43% (n=7) and 34.78% (n=8), respectively. For patients with AMS Ambicore, these percentages were 73.91% (n=17), 13.04% (n=3) and 13.04% (n=3), respectively. These overall satisfaction rates were significantly different between patients with AMS 600-650 and Ambicore (p=0.013). For patients with AMS 600-650, the percentages of patients who reported to be very likely, neither likely nor unlikely, or very unlikely to continue using their prosthesis were 30.43% (n=7), 34.78% (n=8), and 34.78% (n=8) while for patients with AMS Ambicore, these percentages were 65.21%, 21.33%, and 13.04%, respectively. These percentages were different between patients with AMS 600-650 and Ambicore (p=0.018).Conclusion: The two-piece inflatable penile prosthesis was found to be more successful in overall satisfaction and more likely for continued use when compared to the malleable penile prosthesis.
dc.identifier.doi10.5152/tud.2014.37108
dc.identifier.endpage210
dc.identifier.issn2149-3235
dc.identifier.issue4
dc.identifier.startpage207
dc.identifier.urihttps://doi.org/10.5152/tud.2014.37108
dc.identifier.urihttps://www.urologyresearchandpractice.org/en/comparison-of-patient-satisfaction-rates-for-the-malleable-and-two-piece-inflatable-penile-prostheses-132818
dc.identifier.urihttps://hdl.handle.net/11452/46540
dc.identifier.volume40
dc.identifier.wos000420589000003
dc.indexed.wosWOS.ESCI
dc.language.isoen
dc.publisherAves
dc.relation.journalTurkish Journal of Urology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectImplantation
dc.subjectExperience
dc.subjectSafety
dc.subjectEfficacy
dc.subjectOutcomes
dc.subjectErectile dysfunction
dc.subjectPatient satisfaction
dc.subjectPenile prostheses
dc.subjectUrology & nephrology
dc.titleComparison of patient satisfaction rates for the malleable and two piece-inflatable penile prostheses
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublication97a09c20-e30a-413a-8e4b-2e773b1beb77
relation.isAuthorOfPublication7e53dfda-90d9-48ee-acf2-c05fb2b33a29
relation.isAuthorOfPublicationc7166d91-f1a2-4296-b6cf-6666152225e0
relation.isAuthorOfPublication.latestForDiscovery97a09c20-e30a-413a-8e4b-2e773b1beb77

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Kilicarslan_vd_2014.pdf
Size:
272.78 KB
Format:
Adobe Portable Document Format

Collections