dc.description.abstractAimOne-Lung Ventilation (OLV) is widely used in a variety of cardiac, thoracic, and major vascular procedures to ventilate an isolated lung field in humans and dogs. Endobronchial tubes, endobronchial blockers, and single-lumen tubes are commonly using equipments for OLV.Material and MethodsConventional one-lung intermittent positive-pressure ventilation (OL-IPPV) has been a valuable technique during anaesthesia for intrathoracic operations in humans and dogs. Here, our experience resulted in the usage of Pezzer catheter to establish OLV in dogs, while performing tracheobronchial resection. OLV was successfully established with Pezzer catheter in 12 dogs. All application was performed by the same surgeon. An optimal diameter Pezzer catheter was selected to insert into the lumen of the trachea and the main bronchus. The length of the catheter was prepared and middle point of the head of the catheter was cut at the level of holes on it. Following tracheobronchial resection, the cut head was inserted into the trachea with a clamp and end of the catheter was instantly inserted the main bronchus (Figure 1). Sutures were prepared interruptedly and passed between the trachea and the main bronchus. Before sutures were started the ligation tightly, Pezzer catheter was removed in the lumen and than ligations were completed.ResultsNo accidental episode was encountered during the manipulation. OLV was successfully established, and the mean oxygen saturation range and end tidal carbon dioxide concentration was 95% and 37-41% before and after insertion of the Pezzer catheter, respectively. The respiratory modes during the surgery were not need to change.DiscussionOLV is essential in the tracheaobronchial resections. Here, the Pezzer catheter is presented to obtain OLV. It has been concluded that Pezzer catheter is a very practical and reliable method and it can be choice for cases which require OLV.
dc.identifier.doi10.4328/JCAM.335
dc.identifier.endpage83
dc.identifier.issn1309-0720
dc.identifier.issue3
dc.identifier.startpage82
dc.identifier.urihttps://doi.org/10.4328/JCAM.335
dc.identifier.urihttps://hdl.handle.net/11452/47389
dc.identifier.volume2
dc.identifier.wos000215546900028
dc.indexed.wosWOS.ESCI
dc.language.isoen
dc.publisherDerman Medical Publ
dc.relation.journalJournal Of Clinical And Analytical Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectTracheabronchial surgery
dc.subjectPezzer catheter
dc.subjectLung ventilation
dc.subjectScience & technology
dc.subjectLife sciences & biomedicine
dc.subjectMedicine, general & internal
dc.subjectGeneral & internal medicine
dc.titlePezzer catheter to provide one-lung ventilation during tracheobronchial surgery
dc.typeArticle
dspace.entity.typePublication
relation.isAuthorOfPublication3d35a91b-d088-4de4-a6f5-e2e269197423
relation.isAuthorOfPublicationbdb7801d-f0bc-4abc-af2c-5bf7df23fbd5
relation.isAuthorOfPublication.latestForDiscovery3d35a91b-d088-4de4-a6f5-e2e269197423

Files

Collections