A modified continuous suturing technique for amniotic membrane fixation after chemical corneal injury: An octagonal graft

Loading...
Thumbnail Image

Date

2022-10-01

Authors

Baykara, Mehmet
Sarı, Esin Söğütlü
Yurttaş, Ceren
Kırıştıoğlu, Mehmet Ömer

Authors

Journal Title

Journal ISSN

Volume Title

Publisher

Galenos Publ House

Research Projects

Organizational Units

Journal Issue

Abstract

This case report aims to describe a modified continuous suturing technique for firm fixation of a human amniotic membrane graft in a patient with persistent epithelial defect (PED) after a chemical eye injury. As a result of this technique, the amniotic membrane (AM) was firmly fixed to the corneal surface with eight continuous and locked episcleral sutures that resembled an octagon graft. This technique was performed in a 14-year-old patient with PED after a chemical corneal burn. Three weeks after the surgery, the PED was completely healed. This simple continuous suturing technique can allow firm and stable fixation of AM grafts on the ocular surface in cases of PED after chemical burn. It may prevent early loss of the graft and facilitate corneal epithelial wound healing.